CDZDX - ANTI-SEIZE (BT & BULK)
- MSDS: CDZDX
- Manufacturer: RAMCO SPECIALTY PRODUCTS
- Product Name: ANTI-SEIZE (BT & BULK)
- National Stock Number: 8030-00D006864
Product Identification
Product ID:ANTI-SEIZE (BT & BULK)
MSDS Date:01/01/1995
FSC:8030
NIIN:00D006864
MSDS Number: CDZDX
Responsible Party
ANAHEIM, CA 92806-5619
US
Emergency Phone: 800-334-7071
Info Phone: 800-334-7071
Cage: 0AV13
Contractor
Telephone: 714-758-7795/800-334-7071
Cage: 0ZUM2
Ingredients
MINERAL OIL,HYDROTREATED (SEVERE), PETROLEUM DISTILLATE,
CAS: 64742-54-7
RTECS: PY8035501
Fraction By Weight: >35%
GRAPHITE, NATURAL
CAS: 7782-42-5
RTECS: MD9659600
Fraction By Weight: >12%
OSHA PEL 15 MPPCF; Z-3
ACGIH TLV: 2 MG/M3 RDUST; 9495
ALUMINUM (SARA 313)
CAS: 7429-90-5
RTECS: BD0330000
Fraction By Weight: >1%
OSHA PEL 15 MG/M3 DUST
ACGIH TLV: 10 MG/M3 DUST; 9495
COPPER (SARA 313) (CERCLA)
CAS: 7440-50-8
RTECS: GL5325000
Fraction By Weight: >3%
OSHA PEL 0.1MG/M3 FUME/1 DUST
ACGIH TLV: 0.2 MG/M3 FUME; 9495
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
PROPRIETARY MIXTURE
Fraction By Weight: >36%
Hazards
LD50 LC50 Mixture:PRODUCT'S LD50 (ORAL RAT) WAS NOT STATED
Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NO HAZARDS REPORTED AT THIS TIME IN
REFERENCE OR FIELD USAGE.
Explanation of Carcinogenicity:MANUFACTURER GAVE NO INFORMATION ABOUT
CARCINOGENICITY. HMIS FOUND NO LISTING & DOES NOT EXPECT IT TO BE
CARCINOGENIC.
Effects of Overexposure:MFR GAVE NO INFORMATION OF MSDS. POSSIBLE
IRRITATION.
Medical Cond Aggravated by Exposure:MFR GAVE NO INFORMATION OF MSDS.
First Aid
First Aid:EYE & SKIN:FLUSH W/WATER. CONTACT PHYSICIAN IF IRRITATION
PERSSITS. INHALATION:REMOVE TO FRESH AIR. INGESTION:TREAT AS OIL
INGESTION. CONTACT PHYSICIAN.
+
Fire Fighting
Flash Point Method:COC
Flash Point:450F,232C
Autoignition Temp:Autoignition Temp Text:N/A.
Lower Limits:N/A.
Upper Limits:N/A.
Extinguishing Media:USE FOAM, CARBON DIOXIDE OR DRY CHEMICAL.
Fire Fighting Procedures:TREAT AS OIL FIRE. USE SELF-CONTAINED
BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:NONE
Accidental Release
Spill Release Procedures:PICK UP EXCESS. WASH DOWN W/SOLVENT OR STRONG
DETERGENT.
Neutralizing Agent:MFR GAVE NO INFORMATION OF MSDS.
Handling
Handling and Storage Precautions:STANDARD INDUSTRIAL PRACTICES.
Other Precautions:NONE
Exposure Controls
Respiratory Protection:NONE (STANDARD INDUSTRIAL PRACTICES, USUALLY NOT
NEEDED.)
Ventilation:LOCAL EXHAUST
Protective Gloves:NORMALLY NOT NEEDED.
Eye Protection:GLASSES
Other Protective Equipment:NORMALLY NOT NEEDED.
Work Hygienic Practices:STANDARD METHODS
Supplemental Safety and Health
NONE
Chemical Properties
HCC:N1
NRC/State Lic Num:NONE
Boiling Pt:B.P. Text:N/A.
Vapor Pres:N/A.
Vapor Density:N/A.
Spec Gravity:N/A.
Evaporation Rate & Reference:N/A.
Solubility in Water:NIL
Appearance and Odor:COPPERTINTED SOFT GREASE, PETROLEUM ODOR
Percent Volatiles by Volume:N/A.
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS.
Stability Condition to Avoid:OPEN FLAME, ARC WELDING, HIGH TEMPERATURES
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE &
METAL OXIDES
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:LANDFILL OR BURN I/A/W FEDERAL, STATE & LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.